DonatShell
Server IP : 180.180.241.3  /  Your IP : 216.73.216.252
Web Server : Microsoft-IIS/7.5
System : Windows NT NETWORK-NHRC 6.1 build 7601 (Windows Server 2008 R2 Standard Edition Service Pack 1) i586
User : IUSR ( 0)
PHP Version : 5.3.28
Disable Function : NONE
MySQL : ON  |  cURL : ON  |  WGET : OFF  |  Perl : OFF  |  Python : OFF  |  Sudo : OFF  |  Pkexec : OFF
Directory :  /Windows/inf/

Upload File :
current_dir [ Writeable ] document_root [ Writeable ]

 

Command :


[ HOME SHELL ]     

Current File : /Windows//inf/arc.inf
ÿþ;

; Adaptec IOP RAID Host Adapter Drivers

;

; Installation File For Microsoft Windows

;

; Version 1.0

;

; Copyright (c) Adaptec Incorporated

;

; Edited 05/22/07

;



[version]

signature="$Windows NT$"

Class=SCSIAdapter

ClassGUID={4D36E97B-E325-11CE-BFC1-08002BE10318}

Provider=%ADP%

DriverVer=03/21/2007,5.2.0.10384



;

; Source file information

;



[SourceDisksNames]

3426=windows cd



[SourceDisksFiles]

arc.sys = 3426



[DestinationDirs]

DefaultDestDir = 12



[ControlFlags]

ExcludeFromSelect = *



[Manufacturer]

%ADP%=ADAPTEC,NTx86,NTamd64



[ADAPTEC]



[ADAPTEC.NTx86]

%adptVulcan.DeviceDesc% = arc_Inst, PCI\VEN_9005&DEV_0285&SUBSYS_02859005

%adptVulcan.DeviceDesc% = arc_Inst, PCI\VEN_9005&DEV_0285&SUBSYS_02879005

%adptCrusader.DeviceDesc% = arc_Inst, PCI\VEN_9005&DEV_0285&SUBSYS_02869005

%adptSkyhawkscsi.DeviceDesc% = arc_Inst, PCI\VEN_9005&DEV_0285&SUBSYS_028A9005

%adptSkyhawksata.DeviceDesc% = arc_Inst, PCI\VEN_9005&DEV_0285&SUBSYS_028E9005

%adptTerminatorscsi.DeviceDesc% = arc_Inst, PCI\VEN_9005&DEV_0285&SUBSYS_028B9005

%adptTerminatorsata.DeviceDesc% = arc_Inst, PCI\VEN_9005&DEV_0285&SUBSYS_028F9005

%adptJaguar.DeviceDesc% = arc_Inst, PCI\VEN_9005&DEV_0285&SUBSYS_02909005

%adptCorsair8.DeviceDesc% = arc_Inst, PCI\VEN_9005&DEV_0285&SUBSYS_02929005

%adptCorsair16.DeviceDesc% = arc_Inst, PCI\VEN_9005&DEV_0285&SUBSYS_02939005

%adptLancer2ch.DeviceDesc% = arc_Inst, PCI\VEN_9005&DEV_0286&SUBSYS_028C9005

%adptLancer1ch.DeviceDesc% = arc_Inst, PCI\VEN_9005&DEV_0286&SUBSYS_028D9005

%adptBearcat.DeviceDesc% = arc_Inst, PCI\VEN_9005&DEV_0285&SUBSYS_3227103C

%ICPLancer2ch.DeviceDesc% = arc_Inst, PCI\VEN_9005&DEV_0286&SUBSYS_029E9005

%ICPLancer1ch.DeviceDesc% = arc_Inst, PCI\VEN_9005&DEV_0286&SUBSYS_029F9005





[ADAPTEC.NTamd64]

%adptVulcan.DeviceDesc%     	= arc_Inst, PCI\VEN_9005&DEV_0285&SUBSYS_02859005

%adptVulcan.DeviceDesc%     	= arc_Inst, PCI\VEN_9005&DEV_0285&SUBSYS_02879005

%adptCrusader.DeviceDesc%   	= arc_Inst, PCI\VEN_9005&DEV_0285&SUBSYS_02869005	

%adptSkyhawkscsi.DeviceDesc%    = arc_Inst, PCI\VEN_9005&DEV_0285&SUBSYS_028A9005

%adptSkyhawksata.DeviceDesc%    = arc_Inst, PCI\VEN_9005&DEV_0285&SUBSYS_028E9005					

%adptTerminatorscsi.DeviceDesc% = arc_Inst, PCI\VEN_9005&DEV_0285&SUBSYS_028B9005

%adptTerminatorsata.DeviceDesc% = arc_Inst, PCI\VEN_9005&DEV_0285&SUBSYS_028F9005

%adptJaguar.DeviceDesc%     	= arc_Inst, PCI\VEN_9005&DEV_0285&SUBSYS_02909005

%adptCorsair8.DeviceDesc%   	= arc_Inst, PCI\VEN_9005&DEV_0285&SUBSYS_02929005

%adptCorsair16.DeviceDesc%  	= arc_Inst, PCI\VEN_9005&DEV_0285&SUBSYS_02939005

%adptLancer2ch.DeviceDesc% 	= arc_Inst, PCI\VEN_9005&DEV_0286&SUBSYS_028C9005

%adptLancer1ch.DeviceDesc% 	= arc_Inst, PCI\VEN_9005&DEV_0286&SUBSYS_028D9005

%adptBearcat.DeviceDesc%        = arc_Inst, PCI\VEN_9005&DEV_0285&SUBSYS_3227103C

%ICPLancer2ch.DeviceDesc%       = arc_Inst, PCI\VEN_9005&DEV_0286&SUBSYS_029E9005

%ICPLancer1ch.DeviceDesc%       = arc_Inst, PCI\VEN_9005&DEV_0286&SUBSYS_029F9005



;

; arc

;



[arc_Inst]

CopyFiles = @arc.sys



[arc_Inst.Services]

AddService = arc, %SPSVCINST_ASSOCSERVICE%, arc_Service_Inst, Miniport_EventLog_Inst



[arc_Service_Inst]

ServiceType    = %SERVICE_KERNEL_DRIVER%

StartType      = %SERVICE_BOOT_START%

ErrorControl   = %SERVICE_ERROR_NORMAL%

ServiceBinary  = %12%\arc.sys

LoadOrderGroup = SCSI Miniport

AddReg         = pnpsafe_pci_addreg

AddReg         = bus_type_raid





;*************************************************************

;These addreg sections should be used when installing services to indicate

;which interface types are safe for PNP and which aren't.  INTERFACE_TYPE

;is defined in NTDDK.H



[pnpsafe_pci_addreg]

HKR, "Parameters\PnpInterface", "5", 0x00010001, 0x00000001



;************

;MSI

[arc_Inst.HW]

AddReg = MsiEnable_addreg





[MsiEnable_addreg]

; The line may not be needed because LH OS creates other Keys at this same location

; HKR, Interrupt Management, 0x00000010

; Definitely need this Key and value

HKR, Interrupt Management\MessageSignaledInterruptProperties, 0x00000010

HKR, Interrupt Management\MessageSignaledInterruptProperties, MSISupported, 0x00010001, 1



;*************************************************************

;These addreg sections should be used for non-SCSI miniports

;to indicate what STORAGE_BUS_TYPE they actually do support.



[bus_type_raid]

HKR, "Parameters", "BusType", 0x00010001, 0x00000008







;*************************************************************

;The EventLog entries are the same for all SCSI miniports.



[Miniport_EventLog_Inst]

AddReg = Miniport_EventLog_AddReg



[Miniport_EventLog_AddReg]

HKR,,EventMessageFile,%REG_EXPAND_SZ%,"%%SystemRoot%%\System32\IoLogMsg.dll"

HKR,,TypesSupported,%REG_DWORD%,7







[Strings]

;Localizable

ADP = "Adaptec"

adptVulcan.DeviceDesc = "Adaptec SCSI RAID 2200S Controller"

adptCrusader.DeviceDesc = "Adaptec SCSI RAID 2120S Controller"

adptSkyhawkscsi.DeviceDesc = "Adaptec SCSI RAID 2020ZCR Controller"

adptSkyhawksata.DeviceDesc = "Adaptec SATA RAID 2020SA Controller"

adptTerminatorscsi.DeviceDesc = "Adaptec SCSI RAID 2025ZCR Controller"

adptTerminatorsata.DeviceDesc = "Adaptec SATA RAID 2025SA Controller"

adptJaguar.DeviceDesc = "Adaptec SATA RAID 2410SA Controller"

adptCorsair8.DeviceDesc = "Adaptec SATA RAID 2810SA Controller"

adptCorsair16.DeviceDesc = "Adaptec SATA RAID 21610SA Controller"

adptLancer2ch.DeviceDesc = "Adaptec SCSI RAID 2230S Controller"

adptLancer1ch.DeviceDesc = "Adaptec SCSI RAID 2130S Controller"

adptBearcat.DeviceDesc = "Adaptec SATA RAID 2610SA Controller"

ICPLancer2ch.DeviceDesc = "ICP SCSI RAID ICP9024R0 Controller"

ICPLancer1ch.DeviceDesc = "ICP SCSI RAID ICP9014R0 Controller"





;*******************************************

;Non-localizable

SPSVCINST_ASSOCSERVICE = 0x00000002

SERVICE_KERNEL_DRIVER  = 1

SERVICE_BOOT_START     = 0

SERVICE_ERROR_NORMAL   = 1

REG_EXPAND_SZ          = 0x00020000

REG_DWORD              = 0x00010001

Anon7 - 2022
AnonSec Team